2kVA/1600W UPS with 4 Built-in 7ah Batteries, Emergency Time of 15 Minutes

2kVA/1600W UPS with 4 Built-in 7ah Batteries, Emergency Time of 15 Minutes

ModelWall-mounted typeVertical type1KVA2KVA3KVA1KVA2KVA3KVACapacity1KW2KW3KW1KW2KW3KWInputVoltageRangeMinimum switching voltageAt 50% load, 11OVAC +3%; at 100% load, 176VAC+3 %Minimum recovery voltageMinimum switching voltage +10VMaximum switching voltage300VACI3 %Maximum recovery voltageMaximum swi......Keywords:2kVA/1600W UPS with 4 Built-in 7ah Batteries, Emergency Time of 15 Minutes, UPS, 2kVA/1600W

Send Inquiry

Product Description

Model Wall-mounted type Vertical type
1KVA 2KVA 3KVA 1KVA 2KVA 3KVA
Capacity 1KW 2KW 3KW 1KW 2KW 3KW
Input

Voltage
Range
Minimum switching voltage At 50% load, 11OVAC +3%; at 100% load, 176VAC+3 %
Minimum recovery voltage Minimum switching voltage +10V
Maximum switching voltage 300VACI3 %
Maximum recovery voltage Maximum switching voltage -10V
Frequency Range 40-60HZ@50HZ system/50-70HZ@60HZ system
Phase L+ N+PE
Power Factor 100% load z0.99
Output
Output Voltage 208/220/230/240VAC
Output Voltage Accuracy I1%
Frequency Range
(synchronization range)
40-60hz@50HZsystem/50-70HZ@60HZsystem
Frequency Range (battery mode) 50hz+0.1 HZor60HZ+0.1 HZ

Overload
AC Mode 30min@102%-110%Ioad, 10min@110%-130%load 30s@130%-150%Ioad, 500ms@>150 %Ioad
Battery Mode 10min@102%-110%Ioad, 1min@110%-130%load 10s@130%-150%Ioad, 500ms@> 150 %Ioad
Current peak ratio 3:1 (Maximum)
Harmonic distortion 2% ( linear load ) , 5%(non-linear load)
Switching time Mains  Battery Oms
Inverter Bypass 0ms
Effectiveness
AC Mode 95%
Battery Mode 94.8% (20pcs batteries)
Battery

Standard
Battery Number 2 pcs 4 pcs 6 pcs 2 pcs 4 pcs 6 pcs
Charging Current default 1A
Charging Voltage 13.65 x NI1 %

Long Run
Battery Number 3 pcs 6 pcs 8 pcs 3 pcs 6 pcs 8 pcs
Charging Current Preset: 6A110%, 1-12A optional
Charging Voltage 13.65x N*1%
Apperance
Standard Size
Long Width High(mm)
310"438"88 380"438"88 506"438"88 284"145"213 398"145"213 450"192"335
Long Run Size
Long Width High(mm)
310"438"88 380"438"88 380"438"88 284"145"213 398"145"213 398"145"213
Environment
Operating Temperature 0-40°C
Operating Moisture < 95%And no condensation
Operating Altitude < 1000m""
Noise less than 50dB@1Meter
Management
SmartRS-232 Suppon Windows@2000/2003/XP/Vista/2008. Windows@7/8, Linux. Unix and MAC
Optional SNMP Support for power management by SNMP administrator and web browser.
 
2kVA/1600W UPS with 4 Built-in 7ah Batteries, Emergency Time of 15 Minutes
2kVA/1600W UPS with 4 Built-in 7ah Batteries, Emergency Time of 15 Minutes
2kVA/1600W UPS with 4 Built-in 7ah Batteries, Emergency Time of 15 Minutes
 
2kVA/1600W UPS with 4 Built-in 7ah Batteries, Emergency Time of 15 Minutes
2kVA/1600W UPS with 4 Built-in 7ah Batteries, Emergency Time of 15 Minutes
2kVA/1600W UPS with 4 Built-in 7ah Batteries, Emergency Time of 15 Minutes

2kVA/1600W UPS with 4 Built-in 7ah Batteries, Emergency Time of 15 Minutes

Related Category

Send Inquiry

Please Feel free to give your inquiry in the form below. We will reply you in 24 hours.
验证码,看不清楚?请点击刷新验证码